Buyers comparing FTTH drop cable usually meet three model numbers: GJXH, GJYXCH and GJYXFCH. All three are flat "butterfly" drop cables built around bend-insensitive G.657A2 fiber, but they are not interchangeable. The difference is the strength member, and the strength member decides where the cable can be installed.
GJXH — indoor butterfly drop cable. A single FRP or steel wire runs inside the flat core. Designed for in-building runs only.
GJYXCH — self-supporting drop cable with a galvanized steel messenger suspended alongside the flat core, for outdoor aerial drops.
GJYXFCH — identical structure to GJYXCH, but the messenger is FRP (non-metallic). Used where lightning, induced voltage or ground potential rise makes a metallic messenger unsafe.
The table below reflects the typical construction Dongguan Hui Hong Fiber Optic Cable Co., Ltd. ships for each model. Values are indicative; the drum label and the test report always govern the delivered product.
| Item | GJXH | GJYXCH | GJYXFCH |
|---|---|---|---|
| Structure | Indoor butterfly | Self-supporting, steel messenger | Self-supporting, FRP messenger |
| Fiber | G.657A2 (G.652D optional) | G.657A2 (G.652D optional) | G.657A2 (G.652D optional) |
| Fiber count | 1–2 (up to 12 on request) | 1–4 | 1–4 |
| Strength member | FRP or steel wire in core | Approx. 1.0 mm galvanized steel messenger | FRP messenger |
| Outer sheath | LSZH or PVC | LSZH indoor / PE outdoor | LSZH indoor / PE outdoor |
| Typical size | Approx. 2.0 × 3.0 mm | Approx. 2.0 × 3.0 mm + messenger | Approx. 2.0 × 3.0 mm + messenger |
| Short-term tension | 100 N | 600 N carried by the messenger | 600 N carried by the messenger |
| Crush resistance | 1000 N/100 mm | 1000 N/100 mm | 1000 N/100 mm |
| Operating temperature | −20 to +60 °C | −40 to +70 °C (PE) | −40 to +70 °C (PE) |
| Typical span | Indoor runs only | Aerial drop up to ~100 m | Aerial drop up to ~100 m |
Inside the building, from riser to wall outlet: GJXH with LSZH sheath — low smoke, halogen-free, and no messenger to ground or dress.
Pole-to-house aerial drop in a normal environment: GJYXCH — the steel messenger carries the tension, so the fiber inside sees almost none of it.
Aerial drop where lightning exposure or parallel power lines are a concern: GJYXFCH — all-dielectric, no induced voltage on the messenger and no bonding work.
Can GJXH be installed outdoors? Only for very short, protected runs. Its PVC/LSZH sheath is not UV-stabilized and it has no messenger, so a real aerial span needs GJYXCH or GJYXFCH.
What is the difference between GJYXCH and GJYXFCH? Only the messenger material: steel (metallic) versus FRP (non-metallic). Mechanical performance is equivalent; the FRP version removes lightning and induction concerns and the need to bond the messenger.
Which fiber is inside? Bend-insensitive G.657A2 as standard — required for the tight bend radii inside FTTH enclosures and wall outlets. G.652D can be supplied on request.
Need a custom fiber count, sheath or logo print? All three models are built to order — see the OEM/ODM process and MOQ explained on the OEM service page, or request a quote.
If you are weighing the flat butterfly drop against the round outdoor drop, the structural comparison in our guide to outdoor FTTH drop cable construction: GJYXCH and GJYXCFCH explained — same fibre count, different jacket and strength member, compared side by side.
Questions about this article?
Message our engineers on WhatsApp and we will answer with the construction and datasheet you need.
GJXH is the indoor butterfly drop cable: a single FRP or steel wire runs inside the flat core, so it is designed for in-building runs only. For outdoor aerial spans choose the self-supporting GJYXCH or GJYXFCH.
Both are self-supporting drop cables for 1 to 4 fibers. GJYXCH carries a galvanized steel messenger; GJYXFCH replaces it with an FRP messenger. On lightning-prone routes, or wherever induced voltage and ground potential rise exist, the non-metallic GJYXFCH is the safer choice.
All three models are built around bend-insensitive G.657A2 fibre with G.652D optional, so tight corner routing in buildings and FTTH drops does not raise attenuation.