ADSS Cable - Product Range

ADSS cable from Huifiber: all-dielectric self-supporting aerial fiber cable for substation, smart grid and wind farm links, 2-144 cores.

ADSS Cable: All-Dielectric Self-Supporting Optical Cable

ADSS (All-Dielectric Self-Supporting) cable is the standard choice for aerial fibre routes that run along high-voltage transmission lines. Because it contains no metal, it can be installed inside the high-potential zone of a power tower without a separate grounding system and without any risk of induced current reaching the network equipment.

Why All-Dielectric Construction Matters

A conventional aerial cable with a steel messenger wire must be grounded at every pole, which adds cost and creates a conductive path into the substation. ADSS removes that requirement entirely: the aramid yarn strength members carry the mechanical load while remaining electrically invisible to the phase conductors below.

  • No grounding — no bonding, no earthing electrodes, no isolation transformers
  • No induced voltage — safe for linemen working on the tower
  • EMI immunity — optical transmission is unaffected by the electromagnetic field of the line

Sheath Types: PE vs AT

The single most important selection decision for ADSS is the outer sheath. Two options dominate:

  • PE (polyethylene) — the general-purpose sheath. Suitable for spans where the electric field at the cable position is low, typically below 12 kV/m. Lower cost and widely used on medium-voltage routes.
  • AT (anti-tracking) — a specially formulated sheath that resists the dry-band arcing that erodes ordinary PE in strong electric fields. Required where the field exceeds roughly 12 kV/m, or where the cable is installed at the outer field position on a high-voltage tower.

Choosing incorrectly is the most common cause of premature ADSS failure. The field strength at the attachment point — not the nominal line voltage — is what determines the sheath, and it depends on the tower geometry, the phase spacing and where on the crossarm the cable is mounted.

Sag and Span Engineering

ADSS is installed under controlled tension, and the sag must be calculated for the worst-case combined load: wind plus ice plus the cable's own weight. Recommended practice is to keep the maximum working tension below 20-25% of the cable's rated tensile strength (RTS), and the everyday tension below 16-20% of RTS, so the cable retains margin against creep over its 25-year design life.

Typical spans run 100-200 m. Longer spans are possible but reduce the safety margin and may require a higher-grade aramid yarn construction. The installation point on the tower also matters: mounting further from the phase conductors lowers the field strength and can allow a cheaper PE sheath.

Core Counts and Applications

  • 2-12 cores — distribution links, wind farm collector circuits, small substations
  • 24-48 cores — substation-to-substation backhaul, smart grid communications
  • 72-144 cores — trunk routes along transmission corridors, utility backbone

ADSS is also preferred for routes crossing rivers, ravines and railways where trenching is impractical, and for wind farms where the collector network follows the turbine access roads.

Our ADSS Range

Huifiber manufactures ADSS cable in PE and AT sheath grades, from 2 to 144 cores, with standard and bird-peck-resistant (GYFTY83) outer constructions. Every reel is tested for attenuation, tensile strength and sheath integrity before dispatch, and we can supply span calculation support based on your tower geometry and local wind and ice loading.

If you are unsure whether your site needs PE or AT, send us the line voltage, tower type and attachment height and we will advise on the sheath grade and the recommended span.

Frequently Asked Questions

ADSS (All-Dielectric Self-Supporting) cable is the standard choice for aerial fibre routes that must be strung on existing power poles without a separate messenger wire.

What is the maximum span for ADSS cable?

Typical working spans run from about 100 m up to 800 m, and the limiting factor is the span calculation rather than the cable itself. Sag, wind and ice loading, fiber count and sheath type all change the answer, so we run a span calculation against your pole profile and load case before recommending a construction.

ADSS or OPGW — which should I use for an aerial route?

ADSS is all-dielectric and carries no conductive path, so it is the cheaper and simpler option for fibre on distribution lines and where grounding is not required. OPGW combines the functions of a ground wire and a fiber cable, so it is used on transmission lines that genuinely need a grounding conductor.

Can ADSS cable be installed near high-voltage lines?

Yes, that is its main application. The all-dielectric construction and the tracking-resistant outer sheath are designed for the electric field around power lines; the attachment point must still be positioned at a safe potential according to the line voltage and the span calculation.

Which fiber counts and fiber types are available?

We manufacture ADSS cable from 2 up to 288 cores using G652D or G657 single mode fiber, with water-blocked loose-tube cores.

Do you supply the aerial hardware as well?

Yes. Suspension clamps, tension clamps, down-lead clamps and spiral vibration dampers can be supplied with the cable so the whole aerial package arrives together.

Still have a question? Send us your specification and our engineers will reply with a recommendation and a quotation.