Breakout / Distribution Cable

  • GJFJH Indoor Single-Mode Breakout Cable with Tight-Buffered Fibres

Product Features

Tight-Buffered Fiber Structure: Easy to strip, handle, and terminate.  Aramid Yarn Strength Members: 

Provides excellent tensile strength and mechanical protection.  

All-Dielectric Construction: Completely immune to electromagnetic interference (EMI).

High-Performance Outer Jacket: Flame-retardant, corrosion-resistant, water-resistant, and UV-resistant.

Telecom-Grade Fiber Cores: High quality standard ensuring fast transmission speed and low attenuation.

Compact & Lightweight: Small outer diameter and light weight for quick and flexible installation.

GJFJH Indoor Single-mode Breakout Cable: Tight-Buffered Construction

GJFJH is an indoor single-mode breakout cable in which each fibre is individually tight-buffered to 900 µm and separately reinforced, so that any leg can be connectorised and run to its own equipment without a breakout module or splice enclosure. It removes the separate fan-out hardware that loose-tube indoor cable needs, which is why it is the standard choice for backbone runs inside a building.

Construction & Materials

Each fibre is coated to 250 µm, buffered to 900 µm, then covered with a layer of aramid yarn that takes the tensile load before the leg is jacketed as a 2.0 mm subunit. The subunits are cabled together in a single flame-retardant LSZH or OFNR outer jacket. Because every leg carries its own strength member, individual fibres can be pulled, terminated and re-routed without disturbing the rest of the bundle.

Key Features

  • Tight-buffered 900 µm fibre structure — easy to strip, handle and terminate
  • Aramid yarn strength members provide excellent tensile and mechanical protection
  • Each leg is independently reinforced, so no breakout kit is required
  • LSZH flame-retardant outer jacket for indoor riser and plenum routes
  • Available from 4 to 24 cores, with G.652.D or G.657.A1 fibre
  • Connectorised to order with LC, SC or FC

Typical Applications

  • Building backbone between the main distribution frame and floor distributors
  • Data centre inter-rack and intra-rack fibre runs
  • Fibre to the desk in healthcare, finance and broadcast environments
  • Instrumentation racks where individual fibres feed separate terminals

Selection Notes

Choose GJFJH where individual fibres have to reach separate pieces of equipment, and choose a loose-tube indoor cable instead where the run terminates on a single panel — the breakout construction costs more per metre but saves the fan-out hardware and the labour to install it. Size the core count against your final requirement rather than your immediate one: the incremental cost of spare fibres at purchase is a fraction of the cost of pulling a second cable later. Where the route passes through a plenum space, specify the plenum-rated jacket so the cable meets local fire code without a conduit.

FAQ

What is the difference between breakout and distribution cable? In breakout cable each fibre gets its own reinforced 2.0 mm jacket so it can be handled like a patch cord; in distribution cable the fibres are tight-buffered but share one jacket and need a fan-out kit at the ends.

Can the legs be terminated in the field? Yes. The 900 µm tight buffer accepts standard field-installable connectors, and each leg has its own aramid strength member for the crimp.

How many cores can you supply? Standard builds run from 4 to 24 cores, with custom counts and hybrid single-mode/multimode constructions available to order.

Technical Specifications

Cable ModelFiber CountCable Diameter (mm)Cable Weight (kg/km)Allowable Tensile (N) — Long TermAllowable Tensile (N) — Short TermAllowable Crush (N/100mm) — Long TermAllowable Crush (N/100mm) — Short TermBending Radius (mm) — StaticBending Radius (mm) — Dynamic
GJFJH24.1 ± 0.2512.4200660300100020D10D
GJFJH44.8 ± 0.2516.2200660300100020D10D
GJFJH65.1 ± 0.2520.0200660300100020D10D
GJFJH85.6 ± 0.2526.0200660300100020D10D
GJFJH105.8 ± 0.2528.0200660300100020D10D
GJFJH126.2 ± 0.2531.5200660300100020D10D

Standards & compliance: YD/T 1258.2, IEC 60794-2

Values are typical reference data taken from the official Huifiber datasheet. Confirm the final specification against the datasheet before ordering.

Ask about this product on WhatsApp

Frequently Asked Questions

What is the Indoor Single-mode Fiber Optic Cable GJFJH used for?

GJFJH indoor single-mode breakout cable, tight-buffered 900um fibre with aramid yarn. Each leg terminates individually — no fan-out kit needed. 4 to 24 cores.

Can Huifiber customise the Indoor Single-mode Fiber Optic Cable GJFJH?

Yes. Huifiber supplies cable under the buyer's own brand as well as under the Huifiber brand. Fibre count, jacket material, jacket print, drum marking, drum length, packaging and datasheet layout can all be produced to the customer's requirement, and the engineering team can work from a customer specification or adapt an existing construction to a new route requirement.

How is the Indoor Single-mode Fiber Optic Cable GJFJH tested before shipment?

Every production batch is tested before it leaves the plant in Dongguan. Attenuation and geometry are measured on OTDR and optical bench equipment, and mechanical performance is verified against the datasheet for the construction. A factory test report is issued with each shipment, so an incoming inspection can be checked against the same numbers.

What should I send for a Indoor Single-mode Fiber Optic Cable GJFJH quotation?

Send the fibre count and fibre type, the jacket material or fire rating, the route length or span and the drum length you need, the destination port or country, and any certification or test-report requirement. With those details the sales engineer can confirm the construction and return a quotation with an indicative lead time.